We specialize in the design and engineering of FM-200 clean agent fire suppression systems, providing rapid and reliable fire protection that safeguards critical assets without water damage. Our solutions are fully compliant with NFPA 2001 and other applicable standards, environmentally responsible, and engineered for safe operation. Each system is designed for seamless integration with advanced fire detection and building management systems, ensuring optimal performance and protection of sensitive equipment.
- Our Services Include:
- FM-200 Fire Suppression System Design
Customized clean agent systems engineered for fast, effective fire suppression, zero water damage, and full compliance with NFPA 2001. - Hazard Analysis & Protected Area Assessment
Evaluation of room size, equipment sensitivity, and fire risk to determine the correct agent quantity and system configuration. - Agent Flow Calculations & Nozzle Placement
Hydraulic and discharge calculations performed with manufacturer-approved software to ensure effective agent coverage within required discharge times, in accordance with NFPA 2001. - Cylinder & Piping Layout Design
Optimized design of cylinder banks, agent distribution piping, and nozzle placement for uniform coverage and efficient discharge. - Detection & Control Panel Integration
Integration with fire detection systems using cross-zone smoke detection and advanced control logic for automatic release, time delay, abort, and manual operation. - Engineering Documentation, BOQ & Specifications
Preparation of complete design packages including CAD drawings, hydraulic calculation reports, component data sheets, BOQ, and compliance documentation for authority approvals, procurement, and installation.
- Our Design Process Include:
- Site Survey & Risk Assessment
Evaluation of enclosure integrity, ventilation, equipment criticality, and potential fire hazards to define protection objectives. - Concept Design Stage
Development of preliminary layouts, agent quantity estimates, and nozzle placement strategies in compliance with NFPA 2001 and manufacturer guidelines. - Detailed Design Stage
Preparation of a fully coordinated system design, including finalized cylinder layouts, piping network, nozzle placement, hydraulic calculations, and cause-and-effect logic. Integration with fire detection and building management systems is included, along with preparation of technical specifications and BOQ for procurement and installation. - IFC (Issued for Construction) Stage
Finalization and issuance of construction-ready drawings, verified BOQ, and approved technical specifications suitable for installation. - Documentation & Submittals
Delivery of all technical documentation to Authorities Having Jurisdiction (AHJ), consultants, and stakeholders for review, approval, and installation.